Signal assignments for the NuBus row B listed below.
Refer here for NuBus Signal assignments row A, or NuBus Signal pin out row C

Pin # Signal Name Description
1 -12 V -12 VDC
2 GND Ground
3 GND Ground
4 +5 V +5 VDC
5 +5 V +5 VDC
6 +5 V +5 VDC
7 +5 V +5 VDC
8 * Reserved
9 * Reserved
10 * Reserved
11 * Reserved
12 GND Ground
13 GND Ground
14 GND Ground
15 GND Ground
16 GND Ground
17 GND Ground
18 GND Ground
19 GND Ground
20 GND Ground
21 GND Ground
22 GND Ground
23 GND Ground
24 ** Reserved
25 ** Reserved
26 ** Reserved
27 ** Reserved
28 +5 V +5 VDC
29 +5 V +5 VDC
30 GND Ground
31 GND Ground
32 +12 V +12 volts

Google
 

The slash before each of the NUbus signal names indicate that the line is active low.
Back to the main NuBus page for a bus description.
Nubus is obsolete and should not be used for new designs, use the PCIe Interface as an upgrade path.
The NuBus interface is obsolete and should not be used in up-coming designs.
Additional pinout tables for Apple protocols are listed on Apple Computer Buses.

No companies that have been identified that produce components for the NuBus interface.
The interface ICs for NuBus my be out of production.
However this site does include a generic listing of component manufacturers;
Refer to Component Manufacturers, ordered by company first name.


Leroy's Web Page
Home

Electronic Parts and Equipment Distributors Electronic Component Manufacturers OEM Electronic Equipment Manufacturers EDA Software Producers CAD/CAE Software Engineering Standards, Book Stores, and Publications Interface/Embedded Computer Bus Electronic Engineering Design Data Engineering Reference Information.
DistributorsComponents Equipment Software Standards Buses Design Reference
Last Modified 12/15/09
Copyright © 1998 - 2010 All rights reserved Leroy Davis